UNI-T UT33D+ Plus Digital Multimeter with NCV
₨ 2,400
UNI-T UT33D+ Digital Multimeter with NCV and 10A DC Range
The UNI-T UT33D+ digital multimeter packs manual-ranging measurement into a palm-size body. You get DC voltage up to 600 V, AC voltage up to 600 V, DC current up to 10 A, and resistance up to 200 MΩ. A non-contact voltage detector, a continuity buzzer, and a diode test mode cover the checks you run on every dead phone and charging issue. The meter carries a CAT II 600V rating under EN 61010, and the 2000-count LCD includes a backlight. Mechanicpk supplies the UT33D+ to repair shops and technicians across Pakistan who need a dependable first-line meter for battery, charger, and logic board diagnosis.
Out of stock
UNI-T UT33D+ Digital Multimeter for Mobile Repair Benches
The UNI-T UT33D+ digital multimeter gives your repair bench a compact, manual-ranging meter with NCV detection, a loud continuity buzzer, and a 10A DC current range. UNI-T builds the UT33+ series as an entry-level line, and the UT33D+ is the variant that adds the non-contact voltage detector. The LCD reads to 2000 counts, and the meter carries a CAT II 600V rating under EN 61010. For a technician handling a dead phone, a charging issue, or a short on a power rail, that spec set covers the checks you repeat daily: battery voltage, adapter output, trace continuity, and diode behavior. At 134 × 77 × 47 mm, it fits in a bench drawer and in your hand without crowding the microscope area.
Ranges and Accuracy for PCB-Level Diagnosis
DC voltage covers 200 mV, 2 V, 20 V, 200 V, and 600 V with ±(0.5% + 2 digits) accuracy. The 2 V and 20 V ranges match the voltages you meet on battery packs, USB charging lines, and logic board rails, while the 200 mV range lets you compare small drops across a trace. AC voltage reads on 200 V and 600 V ranges at ±(1.2% + 3 digits), which handles mains checks on chargers and bench sockets. DC current spans 2 mA, 20 mA, 200 mA, and 10 A at ±(1% + 2 digits), so you can verify charger output current within those limits. Resistance runs from 200 Ω to 200 MΩ at ±(0.8% + 2 digits), which suits fuse, resistor, and leakage checks. Because you select ranges manually, you decide the resolution of every reading.
NCV, Continuity Buzzer, and CAT II 600V Safety
An NCV multimeter for mobile repair earns its place the first time you test a charger lead or bench power strip. The non-contact detector flags live mains voltage before your probe touches anything. The continuity test sounds an audible buzzer, so you can trace a broken flex cable or a jumper path without looking away from the board. Diode test mode lets you compare readings across a suspected shorted line. Data Hold freezes a reading while you reposition probes, and the backlight keeps the display readable under bench lighting. Auto power-off protects the batteries during long shifts. UNI-T designed the housing with a protective cover and a test lead groove, and the series is specified for drop resistance from 2 meters.
Where the UT33D+ Fits in Your Repair Workflow
Use the UT33D+ at the diagnostic stage, before you reach for a hot air station, a soldering station, or a test box. Check battery and charging voltage first, then confirm continuity on suspect traces and connectors, then run diode-mode comparisons on power lines that behave like a short. Once the fault is isolated, you move on to IC change karna, jumper lagana, or reballing, and you return to the meter to confirm the repair. The meter has no capacitance or temperature function, so it does not replace dedicated tools for those jobs. If your bench outgrows it, step up to an autoranging unit from the Multimeters category, and keep the UT33D+ as your quick second meter at the soldering station or microscope.
| Weight | 0.11 kg |
|---|
Key Features
- ✓Non-contact voltage detection (NCV)
- ✓2000-count backlit LCD
- ✓DC voltage up to 600 V and AC voltage up to 600 V
- ✓DC current up to 10 A
- ✓Resistance up to 200 MΩ
- ✓Continuity buzzer and diode test
- ✓Data Hold, auto power-off, low battery indicator
- ✓CAT II 600V rating, protective cover with test lead groove
Specifications
| Brand | UNI-T |
|---|---|
| Model | UT33D+ |
| Category | Digital Multimeters |
| Compatibility | Universal — not device-specific |
| Supported Devices | Universal — measures any circuit within its rated ranges |
| Technology | LCD display, 2000 counts, manual ranging, NCV detection. DC voltage 200 mV/2 V/20 V/200 V/600 V ±(0.5%+2). AC voltage 200 V/600 V ±(1.2%+3). DC current 2 mA/20 mA/200 mA/10 A ±(1%+2). Resistance 200 Ω to 200 MΩ ±(0.8%+2). Safety rating CAT II 600V, EN 61010 |
| Power Supply | AAA (R03) 1.5 V batteries |
| Dimensions | 134 × 77 × 47 mm |
Common Repair Uses
- ✓Diagnosis and verification across charging, power, and short-circuit faults
- ✓Checking battery voltage on a dead phone
- ✓Testing charger and adapter output voltage and current
- ✓Tracing continuity on broken flex cables and PCB traces
- ✓Diode-mode checks on suspected shorted power lines
- ✓Verifying fuse and resistor values on a logic board
- ✓Detecting live mains voltage with NCV before bench work
- ✓Confirming repairs after jumper lagana or IC change karna
- ✓Isolating charging issue faults at the port and connector
Compatible Devices
- ✓Universal — not device-specific; works on any circuit within the meter’s rated voltage, current, and resistance ranges
- ✓Android smartphone logic boards
- ✓iPhone logic boards
- ✓Smartphone battery packs and battery connectors
- ✓USB chargers and power adapters
- ✓Charging ports and flex cables
- ✓Fuses, resistors, and diodes on repair PCBs
- ✓Bench power supplies and mains sockets
- ✓Tablet and laptop PCB power rails
FAQ
What is the product name?
What is the brand of this product?
What is the model of this product?
What is this product used for?
Which devices are compatible with this product?
Who should use this product?
Is the UNI-T UT33D+ manual ranging or autoranging?
What DC current can the UNI-T UT33D+ measure when testing a phone charger?
Related products
RELIFE RL-004SA silicone pad – Anti-slip
In stock



